The Effect of Cochlear Implant Stimulation on Postural Control
PDF
Cite
Share
Request
Original Investigation
P: 1-6
March 2024

The Effect of Cochlear Implant Stimulation on Postural Control

Turk Arch Otorhinolaryngol 2024;62(1):1-6
1. Department of Otorhinolaryngology Pamukkale University School of Medicine, Denizli, Türkiye
2. Department of Physical Medicine and Rehabilitation Pamukkale University School of Medicine, Denizli, Türkiye
No information available.
No information available
Received Date: 24.12.2023
Accepted Date: 26.03.2024
PDF
Cite
Share
Request

Abstract

Objective

There are contradictory reports on the effect of cochlear implantation on postural control. Associated vestibular loss, electrode insertion trauma, and electrical stimulus of a cochlear implant can influence postural control. This study focused on the electrical stimulation of the cochlea. We aimed to examine whether a cochlear implant's electrical stimulation affects postural control measured by posturography.

Methods

Thirty-three patients with unilateral cochlear implants were included. We used three preprogrammed main tests and their nine subtests in posturography. Postural stability [general stability index (GSI)], fall risk index (FRI), and sensory integration [modified clinical test of sensory integration of balance (m-CTSIB)] were calculated. All tests were performed under three conditions: implant off (1), implant on (2), and implant on music (3).

Results

The mean age was 46.29±16.09 years. GSI was above normal limits in 78% of adult cochlear implant users. We found that FRI was high in 30% of patients, and m-CTSIB was defective in 42%. There were no statistically significant differences in GSI, FRI, and m-CTSIB. Cochlear implant stimulation was found to have positively affected postural control when the subject's data were visualized individually. GSI, FRI, and m-CTSIB dropped to 39%, 24%, and 24%, respectively, when music was on. There was a significant correlation between age and fall index. But this correlation disappeared when music was playing.

Conclusion

Cochlear implant stimulation affected the vestibular system in almost all patients. The effect was positive in most patients.

Keywords: Cochlear implant, postural control, posturography, fall risk, hearing implant, postural balance

Introduction

Cochlear implants (CIs) have become the commonly chosen option to rehabilitate profound or severe sensorineural hearing loss at any age. Although its effects on the hearing system are thoroughly examined, its effects on the vestibular system are still a topic of discussion.

When investigating the interaction between the vestibular system and CIs, various factors must be considered. First, people with severe and profound hearing loss can also have sensory loss in the vestibular end organs. 2.7% of the patients with CIs have been reported to have preoperative dizziness (1).

Furthermore, the risk of falling in older adults with hearing loss was 2.39 times higher than in those without (2). Second, the CI electrode placement is a physical intervention within the sense organ. In addition to the cochlear part, significant damage was observed in the vestibular part in 54% of the samples (3). Vestibular fibrosis, saccular membrane degradation, reactive neuroma, and new bone formation were the most common injuries (4). Third, CIs send continuous electrical signals to the cochlear nerve near the vestibular nerves. Interference with the vestibular system is possible (5).

Vestibular damage has been reported numerous times with organ-specific tests after cochlear implantation surgery. However, the results of the functional tests were inconsistent with the injury. A recent meta-analysis showed that CI surgery had a significant negative effect on caloric test and vestibular evoked myogenic potentials but had no impact on posturography, head impulse test and dizziness handicap inventory (6). Louza et al. (7) measured the risk with portable posturography. They reported that patients with CIs already had a higher risk than usual before surgery, but there was no significant change in fall risk after the surgery.

This study focused on the effect of CIs on functional balance. We aimed to examine whether postural tests are affected by the implant-turn-on/-off conditions. We also aimed to determine whether continuous background sound (continuous electrical stimulation of the cochlear nerve) affected postural balance in patients.

Methods

Participants

Thirty-three patients aged between 16 and 80 years who underwent CI surgery were included in the study. The patients were retrospectively selected from the list and prospectively tested with a posturography. All patients aged over 16 years in our retrospective list were invited to the study. There was no time limit for the duration after surgery. Those with an additional disability, communication problems, bilateral CIs, neurological or psychiatric disease, visual impairment, or orthopedic problems in the lower extremities were not included. None of them were wearing any additional devices like hearing aids during tests. All participants were informed and gave their written informed consent. Permission was obtained from the Pamukkale University Non-invasive Clinical Research Ethics Committee (no: 60116787-020/20941, date: 23.03.2018). The study is registered with clinicaltrials.gov (NCT04404205).

Outcome Measurements

The Biodex Balance System SD (BBS) (Biodex Medical Systems Inc., New York) was used for posturography. The BBS was a valid device for dynamic and static balance assessment (8). The platform was designed to measure postural stability. The reliability was tested in different age groups (9). Three main tests:

Postural stability test: Stable platform with eyes open. The balance of postural stability was measured using three parameters: General stability index (GSI), anterior-to-posterior stability, and median-to-lateral stability. A high score highlights poor balance. When interpreting the results, we used the normal limits mean ±2 standard deviation (SD) (0–1.36) calculated from mean ± SD (0.64±0.36) (10).

Fall risk test (FRI): Unstable platform with eyes open, starting at level 12 and completing at level 1. The device calculates the risk of falling based on the patient’s age and GSI. The higher the value, the higher the risk of falling. When interpreting the results, we accepted the normal limits mean ±2 SD (0.39–3.19) calculated from mean ± SD (1.79±0.70) (10).

Modified clinical test of sensory integration of balance (m-CTSIB): Four subtests were included: i) eyes open firm surface (OF), ii) eyes closed firm surface (CF), and iii) eyes open foam surface (OO), iv) eyes closed foam surface (CO). They provide a detailed evaluation of the relationships between sensory integration and visual, somatosensory, and vestibular stimuli. When interpreting the results, we used normal limits mean ±2 SD (0.66–1.7) calculated from mean ± SD (1.18±0.26) (11).

During the test, the patients were asked to stand on the BBS platform with their hands shoulder-width apart and on their sides in the most comfortable position to maintain balance and be upright. The patient’s foot coordinates were recorded. The tests were carried out at the same time of day (between 10:00 and 14:00). Each patient was informed about the trials and rules. Patients were subjected to a practice study for each condition to eliminate the possible effects of learning and fatigue. All patients were tested three times; each test took 20 seconds and had 10 seconds of rest between tests. The average of the three trials was automatically calculated and recorded by BBS.

All tests were carried out under three conditions:

1. CI off (baseline),

2. CI on,

3. CI on and music on [non-directional music played by multiple speakers from the different parts of the room at a comfortable level (50 dB)]. We chose music rather than simple sounds to represent daily life.

Factors such as age, sex, and implant duration were also studied.

Statistical Analysis

Statistical analysis was performed using the SPSS 10.0 program (Statistical Package for Social Sciences). Results were compared with related samples, Friedman’s two-way analysis of variance, and the t-test for equality of means. The Pearson correlation coefficient was also calculated between the selected pairs. Statistical significance was established at p<0.05 for all analyses.

Results

Thirteen males and 20 females, a total of 33 patients, were tested. The mean age was 46.29±16.09 years at the time of the study. Implantation age was 44.7±16.6 years [minimum (min) 14–maximum (max) 78.5]. The mean duration from implant surgery to test day was 579.12±38.4 days (min 28–max 1463).

All test parameters are summarized in Table 1. No statistically significant differences existed between the three conditions in any of the test parameters. However, when we grouped the patients according to normal and abnormal test results, most patients were seen to be affected to some extent in an increasing or decreasing manner.

GSI was above normal limits in 78% of adult CI users. We found that FRI was high in 30%, and the m-CTSIB composite score was defective in 42% of the patients. CI stimulation was found to have positively affected postural control when the subject’s data were visualized individually. The number of patients with normal GSI increased with increasing stimulation (Figure 1). The FRI was better at baseline. There were 23 normal patients at the beginning of the study (Figure 2). The m-CTSIB composite score was normal in 19 patients at baseline (Figure 3). GSI, FRI, and m-CTSIB dropped to 30%, 21%, and 36%, respectively, when the CI was on. When the music was on, m-CTSIB decreased to 24%, while the other parameters increased slightly.

As expected, age and FRI had a moderate correlation (p=0.004). Interestingly, this correlation disappeared when music was on [implant off (r=0.48, p=0.004), implant on (r=0.429, p=0.011), music on (r=0.317, p=0.068)]. When we divided the patients according to age into three groups [group 1:16-40 years (n=13), group 2: 41-59 years (n=13), group 3: 60 years or above (n=7)], statistically significant differences were found in some test conditions like implant off (FRI, p=0.04), implant on (m-CTSIB-OF, p=0.025), music on (m-CTSIB-OF, p=0.023, m-CTSIB-OO, p=0.043). However, no other statistical difference existed in any of the parameters or test conditions.

There was no correlation between postoperative days and balance. When we divided the group into early [shorter than one year (13 patients)] and late [longer than one year (20 patients)] groups, there were no statistically significant relations in any of the parameters or conditions (p>0.05).

Discussion

In this study, we examined the effect of CI stimulation on postural control. We tested patients under different conditions, such as implant on, implant off, and music playing in the room. There were no significant differences between these conditions in any of the parameters; however, the postural control of several subjects improved with CI stimulation. This effect was most prominent in GSI. An interesting finding of the study was the disappearance of the correlation between age and fall risk when music was played in the room.

After placing the CI, an additional factor is added: sound or electrical stimulation of the cochlear nerve. This hypothesis was first studied with hearing aids. The use of hearing aids helps to maintain postural balance in older adults with hearing loss (12). Postural oscillation improved in 41% of healthy people standing in the dark and those with vestibular insufficiency when a sound stimulus was added to the setting (13). In settings where visual warnings were on, the effect of sound stimulation was minimal (13). Adult patients with bilateral CIs or bimodal hearing solutions were tested with the devices on and off. A 45 dB narrowband white noise from the anterior side was used as a structured sound stimulus. They reported that the sound reduced the patient’s anteroposterior head tilt in the dark when the devices were on (14). In another study, patients with CIs scored lower in the sensory organization test before surgery but approached the normal score in the first year after surgery. The authors concluded that this improvement could be due to increased auditory signals (15).

The effect is more prominent when electrical pulses stimulate the electrode. Biphasic pulse trains at a rate of 900/s improved tilt perception during the subjective visual vertical test in a group of children with CIs (5). However, the gait test yielded conflicting results. When patients with bilateral CIs or bilateral hearing aids were tested in the on/off condition of the devices during gait, there were no significant differences in the on/off states. There was also considerable variation in gait parameters between patients. In the end, the authors suggested that it worked in some specific groups of patients but could not determine a common specification for these patients (16).

Hallemans et al. (17) conducted a more detailed analysis while the patients were walking. Patients with bilateral areflexia and CIs were tested under implant on/off conditions. They also conducted an additional test by playing music from two speakers located at the end of the walkway at a comfortable level. Although there was little difference between the implant on/off conditions, pelvic motion, knee, ankle, and stride length increased, and stride duration was shortened when music was left on in the test room.

The activation in music-assisted environments has an additional positive effect on postural balance (18). We mostly observed a change in patients’ postural conditions when the implant was on.

Interestingly, the positive correlation between age and fall risk index disappeared when music was on. Louza et al. (19) observed comparable results in older adults using music for stimulation. Auditory-motor interactions when playing music have been extensively reviewed extensively (20). Positive effects of music or rhythm were observed in movement disorders. The authors proposed that this effect might be due to the cognitive representation of music and added that further studies were needed to investigate the relationship between music and postural control in vestibular disorders.

Twenty-five children with unilateral implants and bilateral vestibular hypofunction were tested while the implant was turned on and off. The authors used three settings: a double stand with eyes open and closed, a double stand with a dual task, and a transition from a double stand to a single stand. Significant reductions in the anteroposterior and mediolateral displacements were found in the double stance-eyes open condition. They concluded that auditory information positively affected postural balance parameters (21).

There were some limitations in our study. The study group was not evaluated according to the function of the preoperative vestibular system. We used the implant of the condition as a baseline value. The study did not include parameters such as active electrode number, current level, or patient fitness status.

Conclusion

When we looked at individual data, we found that CI stimulation was affecting most patients’ vestibular systems. The positive effect was more prominent than the negative effect. The parameters we used could not explain the difference between negatively and positively affected subjects. The age of the subject might be one of these factors. The disappearance of the positive correlation between age and fall risk when the music was on was supporting evidence.

Further studies using different parameters such as active electrode number, current level, patient fitness status, duration of implant use, directional sound stimulation, and proximity of electrodes to the vestibuler nerve will better understand the effect of CI stimulation on balance.

Ethics Committee Approval: This study was carried out in accordance with the principles of the Declaration of Helsinki. The approval was granted by the Pamukkale University Non-invasive Clinical Research Ethics Committee (no: 60116787-020/20941, date: 23.03.2018).

Informed Consent: All participants were informed and gave their written informed consent.

Authorship Contributions

Surgical and Medical Practices: F.N.A., F.T., A.A., F.A., Concept: F.N.A., F.T., A.A., F.A., Design: F.N.A., F.T., A.A., F.A., Data Collection and/or Processing: F.N.A., F.T., A.A., F.A., Analysis and/or Interpretation: F.N.A., F.T., A.A., F.A., Literature Search: F.N.A., F.T., A.A., F.A., Writing: F.N.A., F.T., A.A., F.A.

Conflict of Interest: The authors have no conflicts of interest to declare.

Financial Disclosure: The authors declared that this study has received no financial support.

Main Points

• The postural stability index was beyond normal limits in 78% of adult cochlear implant (CI) users.

• We found the fall risk index was high in 30%, and sensorimotor control was defective in 42% of patients.

• When the CI was on, the positive effect on postural stability was more prominent than the negative effect.

• Additional music also increased this positive effect in some patients.

• We could not find any specific parameter to explain the difference between patients affected positively and negatively.

• Age might be one of these factors, according to our data.  

References

1
Hänsel T, Gauger U, Bernhard N, Behzadi N, Romo Ventura ME, Hofmann V, et al. Meta-analysis of subjective complaints of vertigo and vestibular tests after cochlear implantation. Laryngoscope. 2018; 128: 2110-23.
2
Jiam N, Li C, Agrawal Y. Hearing loss and falls: a systematic review and meta-analysis. Laryngoscope. 2016; 126: 2587-96.
3
Cushing SL, Papsin BC. Cochlear implants and children with vestibular impairments. Semin Hear. 2018; 39: 305-20.
4
Tien HC, Linthicum FH Jr. Histopathologic changes in the vestibule after cochlear implantation. Otolaryngol Head Neck Surg. 2002; 127: 260-4.
5
Gnanasegaram JJ, Parkes WJ, Cushing SL, McKnight CL, Papsin BC, Gordon KA. Stimulation from cochlear implant electrodes assists with recovery from asymmetric perceptual tilt: evidence from the subjective visual vertical test. Front Integr Neurosci. 2016; 10: 32.
6
Ibrahim I, da Silva SD, Segal B, Zeitouni A. Effect of cochlear implant surgery on vestibular function: meta-analysis study. J Otolaryngol Head Neck Surg. 2017; 46: 44.
7
Louza J, Klappert CL, Ledderose G, Gürkov R, Krause E. Cochlear implant surgery and the risk of falls in an adult population. Otol Neurotol. 2018; 39: e74-9.
8
Arifin N, Abu Osman NA, Wan Abas WA. Intrarater test-retest reliability of static and dynamic stability indexes measurement using the Biodex Stability System during unilateral stance. J Appl Biomech. 2014; 30: 300-4.
9
Parraca JA, Olivares PR, Carbonell-Baeza A, Aparicio VA, Adsuar JC, Gusi N. Test-retest reliability of Biodex Balance SD on physically active old people. Journal of Human Sport and Exercise. 2011; 6: 444-51.
10
Özsoy G, İlçin N. The impact of non-specific low back pain on postural control, balance, fall, mobility and physical activity in elderly individuals: a comparative study. Turk J Physiother Rehabil. 2021; 32: 67-73.
11
Dawson N, Dzurino D, Karleskint M, Tucker J. Examining the reliability, correlation, and validity of commonly used assessment tools to measure balance. Health Sci Rep. 2018; 1: e98.
12
Negahban H, Bavarsad Cheshmeh Ali M, Nassadj G. Effect of hearing aids on static balance function in elderly with hearing loss. Gait Posture. 2017; 58: 126-9.
13
Stevens MN, Barbour DL, Gronski MP, Hullar TE. Auditory contributions to maintaining balance. J Vestib Res. 2017; 26: 433-8.
14
Shayman CS, Mancini M, Weaver TS, King LA, Hullar TE. The contribution of cochlear implants to postural stability. Laryngoscope. 2018; 128: 1676-80.
15
Parietti-Winkler C, Lion A, Montaut-Verient B, Grosjean R, Gauchard GC. Effects of unilateral cochlear implantation on balance control and sensory organization in adult patients with profound hearing loss. Biomed Res Int. 2015; 2015: 621845.
16
Weaver TS, Shayman CS, Hullar TE. The effect of haring aids and cochlear implants on balance during gait. Otol Neurotol. 2017; 38: 1327-32.
17
Hallemans A, Mertens G, Van de Heyning P, Van Rompaey V. Playing music may improve the gait pattern in patients with bilateral caloric areflexia wearing a cochlear implant: results from a pilot study. Front Neurol. 2017; 8: 404.
18
Buchman CA, JoyJ, Hodges A, Telischi FF, Balkany TJ. Vestibular effects of cochlear implantation. Laryngoscope. 2004; 114: 1-22.
19
Louza J, Rösel C, Gürkov R, Krause E, Ihler F. Influence of cochlear implantation on postural control and risk of falls. Audiol Neurotol. 2019; 24: 245-52.
20
Zatorre RJ, Chen JL, Penhune VB. When the brain plays music: auditory-motor interactions in music perception and production. Nat Rev Neurosci. 2007; 8: 547-58.
21
Mazaheryazdi M, Moossavi A, Sarrafzadah J, Talebian S, Jalaie S. Study of the effects of hearing on static and dynamic postural function in children using cochlear implants. Int J Pediatr Otorhinolaryngol. 2017; 100: 18-22.
2024 ©️ Galenos Publishing House